Accurate time-resolved force measurements for complex experimental systems are important for minimizing erroneous and misleading data. These measurements become difficult when a natural frequency of the system is in or near the expected frequency domain of the time-varying force being applied. In the cases where it is not possible to avoid this occurrence, the experimenter typically abandons the setup. This work presents an inverse filter method to compensate for the dynamic response of the measurement system. A two degree-of-freedom measurement system is used to obtain force measurements with dominant forcing frequencies above and below the first natural frequency of the system. The results show that inverse filtering can be used along with digital low pass filters to correct amplification and phase shift due to the dynamic response of the measurement system to within +/- 4.0% of total forcing amplitude and +/- 5.0 degrees. A simple cam follower mechanism is proposed as a method of low-frequency dynamic testing.