Point-of-care lung ultrasound patterns in late third-trimester gravidas with and without preeclampsia

American Journal of Obstetrics & Gynecology MFM(2021)

Cited 6|Views3
No score
Abstract
BACKGROUND: Transthoracic point-of-care ultrasonography of the lungs has become a standard technique in critical care medicine for the evaluation of patients with respiratory signs or symptoms but has not been well studied in pregnancy.OBJECTIVE: To compare lung ultrasound patterns in third-trimester gravidas with and without preeclampsia and assess interobserver agreement between 3 obstetrical providers and a physician expert in critical care lung ultrasound.STUDY DESIGN: This is a prospective observational study of 262 women with singleton pregnancies between 32 0/7 and 41 6/7 weeks' gestation. Lung ultrasound examinations were performed and interpreted by a team of obstetrical care providers and then interpreted by an expert in point-of-care lung ultrasound. The number of B-lines in each of the 4 lung fields, indicating the accumulation of fluid in the interstitial space and the alveoli, was evaluated. The primary outcome was a positive study for pulmonary interstitial edema, defined as an ultrasound study with 3 or more B-lines in 2 or more bilateral lung fields. The secondary outcome was a lung ultrasound study with 1 or 2 B-lines in 1 or more lung fields or 3 B-lines in 1 lung field. Interobserver agreement in lung ultrasound interpretation between obstetrical care providers and an expert in critical care point-of-care ultrasonography of the lung was assessed.RESULTS: Among healthy gravidas, no subject had a lung ultrasound examination positive for pulmonary interstitial edema. Notably, 2 patients with preeclampsia had positive lung ultrasound studies, and both had respiratory symptoms or signs of pulmonary edema. One or 2 B-lines or 3 B-lines in 1 lung field were identified in 11.4% of healthy gravidas and 18.6% of patients with preeclampsia. There was no difference in lung ultrasound patterns between healthy gravidas and those with preeclampsia. The obstetrical care providers and the lung ultrasound expert had a high proportion of agreement regarding the interpretation of negative lung ultrasound examinations. The 2 patients with clinical signs of pulmonary edema were judged to have positive studies by both the obstetrical team and the expert; however, the obstetrical team classified more studies as positive.CONCLUSION: Lung ultrasound patterns in women with preeclampsia without respiratory symptoms or clinical signs of pulmonary edema are similar to the lung ultrasound patterns of healthy gravidas. Point-of-care lung ultrasound can be used to evaluate third-trimester gravidas with preeclampsia and respiratory complaints or signs concerning for pulmonary edema. Formal training is important before the widespread adoption of point-of-care lung ultrasound by obstetrical healthcare providers.
More
Translated text
Key words
lung ultrasound,POCUS,thoracic point-of-care ultrasound,preeclampsia,pregnancy,pulmonary edema
AI Read Science
Must-Reading Tree
Example
Generate MRT to find the research sequence of this paper
Chat Paper
Summary is being generated by the instructions you defined