Accuracy of antigen and nucleic acid amplification testing on saliva and naopharyngeal samples for detection of SARS-CoV-2 in ambulatory care

S. Kerneis, C. Elie,J. Fourgeaud, L. Choupeaux, S. Mercier Delarue, M. L. Alby, P. Quentin, J. Pavie, P. Brazille,M. L. Nere, M. Minier,A. Gabassi, A. Gibaud,S. Gauthier, C. Leroy, E. Voirin Mathieu, C. Poyart, M. Vidaud, B. Parfait,C. Delaugerre, J. M. Treluyer, J. Le Goff

medRxiv(2021)

引用 9|浏览5
暂无评分
摘要
Background: Nasopharyngeal sampling for nucleic acid amplification testing (NAAT) is the current standard diagnostic test for of coronavirus disease 2019 (COVID-19). However, the NAAT technique is lengthy and nasopharyngeal sampling requires trained personnel. Saliva NAAT represents an interesting alternative but diagnostic performances vary widely between studies. Objective: To assess the diagnostic accuracy of a nasopharyngeal point-of-care antigen (Ag) test and of saliva NAAT for detection of severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2), as compared to nasopharyngeal NAAT. Design: Prospective participant enrollment from 19 October through 18 December 2020. Setting: Two community COVID-19 screening centers in Paris, France. Participants: 1452 ambulatory children and adults referred for SARS-CoV-2 testing. Interventions: NAAT on a saliva sample (performed with three different protocols for pre-processing, amplification and detection of SARS-CoV-2) and Ag testing on a nasopharyngeal sample. Measurements: Performance of saliva NAAT and nasopharyngeal Ag testing. Results: Overall, 129/1443 (9%) participants tested positive on nasopharyngeal NAAT (102/564 [18%] in symptomatic and 27/879 [3%] in asymptomatic participants). Sensitivity was of 94% (95% CI, 86% to 98%), 23% (CI, 14% to 35%), 94% (CI, 88% to 97%) and 96% (CI, 91% to 99%) for the nasopharyngeal Ag test and the three different protocols of saliva NAAT, respectively. Estimates of specificity were above 95% for all methods. Diagnostic accuracy was similar in symptomatic and asymptomatic individuals. Limitations: Few children (n=122, 8%) were included. Conclusion: In the ambulatory setting, diagnostic accuracy of nasopharyngeal Ag testing and of saliva NAAT seems similar to that of nasopharyngeal NAAT, subject to strict compliance with specific pre-processing and amplification protocols. Registration number: NCT04578509 Funding Sources: French Ministry of Health and the Assistance Publique-Hopitaux de Paris Foundation.
更多
查看译文
关键词
nucleic acid amplification testing,naopharyngeal samples,antigen,saliva,sars-cov
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要