Diagnostic Accuracy Of [C-11]Pib Positron Emission Tomography For Detection Of Cardiac Amyloidosis

JACC-CARDIOVASCULAR IMAGING(2020)

Cited 38|Views5
No score
Abstract
OBJECTIVES This dual-site study evaluated the diagnostic accuracy of the method.BACKGROUND Pittsburgh compound ([C-11]PIB) positron emission tomography (PIB-PET) has shown promise as a specific and noninvasive method for the diagnosis of cardiac amyloidosis (CA).METHODS The study had 2 parts. In the initial study, 51 subjects were included, 36 patients with known CA and increased wall thickness (15 immunoglobulin light chain [AL] and 21 transthyretin [ATTR] amyloidosis) and 15 control patients (7 were nonamyloid hypertrophic and 8 healthy volunteers). Subjects underwent PIB-PET and echocardiography. Sensitivity and specificity of PIB-PET were established for 2 simple semiquantitative approaches, standardized uptake value ratio (SUVR) and retention index (RI). The second part of the study included (11) amyloidosis patients (5 AL and 6 hereditary ATTR) without increased wall thickness to which the optimal cutoff values of SUVR (>1.09) and RI (>0.037 min-1) were applied prospectively.RESULTS The diagnostic accuracy of visual inspection of [C-11]PIB uptake was 100% in discriminating CA patients with increased wall thickness from controls. Semiquantitative [C-11]PIB uptake discriminated CA from controls with a 94% (95% confidence interval [CI]: 80% to 99%) sensitivity for both SUVR and RI and specificity of 93% (95% CI: 66% to 100%) for SUVR and 100% (95% CI: 75% to 100%) for RI. [C-11]PIB uptake was significantly higher in AL-CA than in ATTR-CA patients (p < 0.001) and discriminated AL-CA from controls with 100% (95% CI: 88% to 100%) accuracy for both the semiquantitative measures. In the prospective group without increased wall thickness, RI was elevated compared to controls (p = 0.001) and 5 of (11) subjects were evaluated as [C-11]PIB PET positive.CONCLUSIONS In a dual-center setting, [C-11]PIB PET was highly accurate in detecting cardiac involvement in the main amyloid subtypes, with 100% accuracy in AL amyloidosis. A proportion of amyloidosis patients without known cardiac involvement were [C-11]PIB PET positive, indicating that the method may detect early stages of CA. (c) 2020 by the American College of Cardiology Foundation.
More
Translated text
Key words
diagnosis, heart, nuclear imaging, PET, Pittsburgh compound B
AI Read Science
Must-Reading Tree
Example
Generate MRT to find the research sequence of this paper
Chat Paper
Summary is being generated by the instructions you defined