谷歌浏览器插件
订阅小程序
在清言上使用

Flow Accelerated Corrosion Rate on Carbon Steel Pipe Bend by Thin Layer Activation Technique and Computational Modeling: under PHWR Operating Conditions

P. Madasamy,P. Chandramohan, M. Mukunthan,T. V. Krishna Mohan,S. Rangarajan, Niraj Uttam, R. Ramakrishnan, G. Babulal,H. P. Rani,P. Surendran, A. K. Gupta,J. P. Nair

Engineering failure analysis(2021)

引用 6|浏览6
暂无评分
摘要
Carbon Steel (CS) piping plays a vital role in the heat transport circuits of power plants. These pipes undergo excessive degradation in some of the specific locations due to the flow dynamics variation and such corrosion is termed as the flow accelerated corrosion (FAC). The corrosion rate is usually estimated at a specific location based on one of the best available technique known as the Think Layer Activation (TLA) method. In the present study this method was adopted for the estimation of CS pipe corrosion with 50NB Sch 160, bend angle of 58 degrees and 4D bend radius (D-pipe diameter). Irradiated location was chosen based on the turbulence patterns in the bend as mapped by CFD analysis. At the specified location the corrosion rate to be monitored was irradiated with the proton beam of 13.3 MeV energy aiming for the nuclear reaction of Fe-56(p,n) Co-56. This irradiated specimen was welded to the High Temperature High Pressure (HTHP) loop and operated at 290 degrees C/87 bar. The chemistry parameters like pH (10.2) and DO (< 5 ppb) in the loop were maintained by suitably adding LiOH and N2H4. Corrosion rate was assessed by measuring the radioactivity decrease due to corrosion. Throughout the experimental duration the radioactivity measurement was carried on the CS pipe surface at the fixed distance locations. The flow structure in the considered geometry is simulated using CFD. The flow field, velocity, is used to calculate the wall shear stress and mass transfer coefficient. The corrosion rate is calculated with the help of Chilton-Calbourn Equation. It is observed that the computed corrosion rate for this CS pipe under this chemistry and geometry conditions was 400um/y which coincides with that of the TLA method.
更多
查看译文
关键词
Carbon steel,Magnetite,PHWR,Thin layer activation,Flow accelerated corrosion
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要