The influence of suture materials on the biomechanical behavior of suture-meniscal specimens: a comparative study in a porcine model

Knee Surgery & Related Research(2020)

引用 9|浏览9
暂无评分
摘要
Background Repair of a meniscal tear is indicated in certain conditions. Despite extensive research on the biomechanics of various repair methods, there has been minimal investigation of whether the suture material influences the meniscal-suture construct. The purpose of this study was to compare the biomechanical properties of nine different suture materials under cyclic and load-to-failure conditions. Methods Ninety porcine menisci were randomly allocated to simple suture placement using either Ultrabraid®, Ultratape®, Magnum Wire®, TigerWire®, TigerTape®, LabralTape®, Orthocord®, 0 FiberWire®, or 2-0 FiberWire®. Each suture-meniscus specimen underwent cyclic loading followed by load-to-failure testing. Elongation, maximum load to failure, stiffness, and mode of failure were recorded and compared between each suture type using non-parametric testing. Mean ± standard deviation was reported and the statistical significance was p < 0.05. Results Elongation during cyclic loading was lowest with 2-0 FiberWire (0.95 ± 0.17 mm); this value was statistically significantly different than the results for all other sutures except 0 FiberWire® (1.09 ± 0.17 mm, p = 0.79), TigerWire® (1.09 ± 0.29 mm, p = 0.85), TigerTape® (1.39 ± 0.29 mm, p = 0.08), and LabralTape® (1.20 ± 0.33 mm, p = 0.41). The highest elongation was seen with Ultrabraid® (1.91 ± 0.34 mm); this value was statistically significantly greater than the results for all other suture materials except Orthocord® (1.59 mm ± 0.31 mm, p = 0.46) and Magnum Wire® (1.43 ± 0.25 mm, p = 0.14). Load to failure was highest for TigerTape® (287.43 ± 41.15 N), and this result was statistically significantly different than the results for all other sutures except LabralTape® (271.34 ± 48.48 N, p = 0.99) and TigerWire® (251.03 ± 25.8 N, p = 0.51). Stiffness was highest for LabralTape® (195.77 ± 49.06 N/mm), and this result was statistically significantly different than the results for all other sutures except TigerWire® (186.49 ± 19.83 N/mm, p = 0.45) and TigerTape® (173.35 ± 15.60 N/mm, p = 0.19). The majority of sutures failed by pullout ( n = 46, 51%) or tearing ( n = 40, 45%). Conclusion Suture design and material affect the biomechanical behavior of porcine meniscal-suture specimens. LabralTape®, TigerWire®, and TigerTape® demonstrated better overall combinations of low elongation, high maximum load to failure, and high stiffness.
更多
查看译文
关键词
Meniscal tears,Meniscus repair,Suture repair,Biomechanical analysis,Porcine
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要