谷歌浏览器插件
订阅小程序
在清言上使用

A Comparative Study Of Three Commonly Used Fixation Techniques For Isolated Medial Malleolus Fracture

EKLEM HASTALIKLARI VE CERRAHISI-JOINT DISEASES AND RELATED SURGERY(2018)

引用 12|浏览10
暂无评分
摘要
Objectives: This study aims to compare the three most commonly used fixation techniques: tension-band wire fixation. partially threaded cannulated screws, and fully threaded cannulated headless compression screws.Patients and methods: Ninety patients with medial malleolus fractures were included in the study. Patients were divided into three groups. Group A included patients who underwent tension-band wire fixation (n=26), Group B partially threaded cannulated compression screws (n=32), and Group C fully threaded cannulated headless compression screws (n=32). The type of medial malleolus fracture. healing rates, implant-related complications, rate of infection, hardware removal weight-bearing restrictions. mean interval time from the injury to the surgery, and Body Mass Indexes (BMIs) were investigated. The patients' radiographs (standard anteroposterior, lateral, and mortise) were reviewed. The American Orthopedic Foot and Ankle Society (AOFAS) scoring system was used for clinical evaluation.Results: No significant difference was observed between the three groups in terms of age, gender, BMI, follow-up period, and fracture type. Union rate for group C was significantly shorter than groups A and B. There was no implant failure or irritation in group C and this was statistically significant comparing to group A and B (p=0.037). However. there was no significant difference between group A and B (p=0.41). There were no significant differences in the three groups according to AOFAS. Patients with low BMI in groups A and B had a high rate of implant-related complications. There was a significant correlation between low BMI and implant-related complication (p<0.001).Conclusion: Union rate in the group who were operated with fully threaded cannulated headless compression screws was significantly shorter than the other groups. This study has shown that tension band wiring and partially threaded cannulated compression screws can cause irritation of soft tissues and pain over the hardware implantation site. Patients with low BMI are vulnerable for implant-related complications.
更多
查看译文
关键词
Ankle fracture,body mass index,headless cannulated compression screws,medial malleolus fracture,partially threaded cannulated compression screws,tension band wiring
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要