Chrome Extension
WeChat Mini Program
Use on ChatGLM

Maintenance of Segmental Lordosis and Disk Height in Stand-alone and Instrumented Extreme Lateral Interbody Fusion (XLIF)

Clinical Spine Surgery(2014)

Cited 93|Views6
No score
Abstract
Study Design: A prospective single-surgeon nonrandomized clinical study. Objective: To evaluate the radiographic and clinical outcomes, by fixation type, in extreme lateral interbody fusion (XLIF) patients and provide an algorithm for determining patients suitable for stand-alone XLIF. Summary of Background Data: XLIF may be supplemented with pedicle screw fixation, however, since stabilizing structures remain intact, it is suggested that stand-alone XLIF can be used for certain indications. This eliminates the associated morbidity, though subsidence rates may be elevated, potentially minimizing the clinical benefits. Materials and Methods: A fixation algorithm was developed after evaluation of patient outcomes from the surgeon’s first 30 cases. This algorithm was used prospectively for 40 subsequent patients to determine the requirement for supplemental fixation. Preoperative, postoperative, and 12-month follow-up computed tomography scans were measured for segmental and global lumbar lordosis and posterior disk height. Clinical outcome measures included back and leg pain (visual analogue scale), Oswestry Disability Index (ODI), and SF-36 physical and mental component scores (PCS and MCS). Results: Preoperatively to 12-month follow-up there were increases in segmental lordosis (7.9–9.4 degrees, P =0.0497), lumbar lordosis (48.8–55.2 degrees, P =0.0328), and disk height (3.7–5.5 mm, P =0.0018); there were also improvements in back (58.6%) and leg pain (60.0%), ODI (44.4%), PCS (56.7%), and MCS (16.1%) for stand-alone XLIF. For instrumented XLIF, segmental lordosis (7.6–10.5 degrees, P =0.0120) and disk height (3.5–5.6 mm, P <0.001) increased, while lumbar lordosis decreased (51.1–45.8 degrees, P =0.2560). Back (49.8%) and leg pain (30.8%), ODI (32.3%), PCS (37.4%), and MCS (2.0%) were all improved. Subsidence occurred in 3 (7.5%) stand-alone patients. Conclusions: The XLIF treatment fixation algorithm provided a clinical pathway to select suitable patients for stand-alone XLIF. These patients achieved positive clinical outcomes, satisfactory fusion rates, with sustained correction of lordosis and restoration of disk height.
More
Translated text
Key words
disk height,instrumented,lateral,lordosis,minimally invasive,stand-alone
AI Read Science
Must-Reading Tree
Example
Generate MRT to find the research sequence of this paper
Chat Paper
Summary is being generated by the instructions you defined