谷歌浏览器插件
订阅小程序
在清言上使用

Heat Removal Performance Evaluation of Several Passive Containment Cooling Systems during Loss of Coolant Accident.

JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY(2012)

引用 1|浏览2
暂无评分
摘要
As a passive containment cooling system (PCCS), which is adopted in simplified BWRs, several concepts, differing in cooling location and method, such as the suppression chamber water wall, the drywell water wall, the isolation condenser (I/C) and the drywell cooler, have been considered. This paper summarizes the characteristics of each PCCS concept, and the analysis results of the performance for several PCCSs during a main steam line break LOCA for a reference simplified BWR plant, obtained by the newly developed containment thermal-hydraulic response analysis code TOSPAC. The performance comparison suggests that I/C and drywell cooler have good heat removal capability with regard to the smallest heat transfer area among PCCS concepts evaluated in the present analysis. I/C removes decay heat efficiently, since it absorbs steam directly from the reactor pressure vessel, which is the hottest portion inside the containment. The suppression chamber water wall is ineffective, mainly due to high non-condensable gas partial pressure in the suppression chamber, and low suppression pool temperature. Calculations of other pipe breaks were also implemented for the reference plant adopting I/C as PCCS. The results show the effectiveness of the I/C cooling over a wide range of break spectra.
更多
查看译文
关键词
BWR TYPE REACTORS,LOSS OF COOLANT,THERMAL-HYDRAULICS,COMPUTER CODES,ANALYSIS,PERFORMANCE,PASSIVE CONTAINMENT COOLING SYSTEM,WATER WALL,ISOLATION CONDENSER
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要