An LC-MS/MS method for determination of the bromodomain inhibitor ZEN-3694 and its metabolite ZEN-3791 in human plasma

Ye Feng,Haider Mahdi,Richard Piekarz, Jan H. Beumer, Timothy W. Synold

BIOANALYSIS(2024)

引用 0|浏览0
暂无评分
摘要
We have developed and validated a novel LC-MS/MS method for the simultaneous quantification of ZEN-3694 and its active metabolite ZEN-3791 in human plasma after protein precipitation. Stable isotope-labeled versions were used as internal standards. Chromatographic separation was achieved on a Kinetex C18 column using 0.1% formic acid in H2O and 0.1% formic acid in MeOH as mobile phases. Detection was performed via positive electrospray ionization mode with multiple reaction monitoring. The assay exhibited linearity in the concentration range of 5-5000 ng/ml for both analytes. Intra- and inter-assay precision and accuracy were within +/- 11%. ZEN-3694 and ZEN-3791 recoveries were between 93 and 105%. This LC-MS/MS assay is an essential tool to study ZEN-3694 in an ongoing clinical trial (NCT04840589).
更多
查看译文
关键词
assay,BET bromodomain inhibitor,chromatography,clinical,LC-MS,mass spectrometry,ZEN-3694,ZEN-3791
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要