Clinical evaluation of isotropic MAVRIC-SL for symptomatic hip arthroplasties at 3 T MRI

Magnetic Resonance Imaging(2024)

引用 0|浏览1
暂无评分
摘要
Background 3D multi-spectral imaging (MSI) of metal implants necessitates relatively long scan times. Objective We implemented a fast isotropic 3D MSI technique at 3 T and compared its image quality and clinical utility to non-isotropic MSI in the evaluation of hip implants. Methods Two musculoskeletal radiologists scored images from coronal proton density-weighted conventional MAVRIC-SL and an isotropic MAVRIC-SL sequence accelerated with robust-component-analysis on a 3-point scale (3: diagnostic, 2: moderately diagnostic, 1: non-diagnostic) for overall image quality, metal artifact, and visualization around femoral and acetabular components. Grades were compared using a signed Wilcoxon test. Images were evaluated for effusion, synovitis, osteolysis, loosening, pseudotumor, fracture, and gluteal tendon abnormalities. Reformatted axial and sagittal images for both sequences were subsequently generated and compared for image quality with the Wilcoxon test. Whether these reformats increased diagnostic confidence or revealed additional pathology, including findings unrelated to arthroplasty that may contribute to hip pain, was also compared using the McNemar test. Inter-rater agreement was measured by Cohen's kappa. Results 39 symptomatic patients with a total of 59 hip prostheses were imaged (mean age, 70 years ±9, 14 males, 25 females). Comparison scores between coronal images showed no significant difference in image quality, metal artifact, or visualization of the femur and acetabulum. Except for loosening, reviewers identified more positive cases of pathology on the original coronally-acquired isotropic sequence. In comparison of reformatted axial and sagittal images, the isotropic sequence scored significantly (p < 0.01) higher for overall image quality (3.0 vs 2.0) and produced significantly (p < 0.01) more cases of increased diagnostic confidence (42.4% vs 7.6%) or additional diagnoses (50.8% vs 22.9%). Inter-rater agreement was substantial (k = 0.798) for image quality. Mean scan times were 4.2 mins (isotropic) and 7.1 mins (non-isotropic). Conclusion Compared to the non-isotropic sequence, isotropic 3D MSI was acquired in less time while maintaining diagnostically acceptable image quality. It identified more pathology, including postoperative complications and potential pain-generating pathology unrelated to arthroplasty. This fast isotropic 3D MSI sequence demonstrates promise for improving diagnostic evaluation of symptomatic hip prostheses at 3 T while simultaneously reducing scan time.
更多
查看译文
关键词
3 T MRI,Hip arthroplasty,Postoperative complications,Fast isotropic imaging,Metal artifact reduction
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要