MnO2-based capacitive system enhances ozone inactivation of bacteria by disrupting cell membrane

Xiyuan Zheng,Tao Zhong, Huinan Zhao, Fan Huang, Wenbin Huang,Lingling Hu, Dehua Xia,Shuanghong Tian, Dong Shu,Chun He

Water Research(2024)

引用 0|浏览2
暂无评分
摘要
The application of ozone (O3) disinfection has been hindered by its low solubility in water and the formation of disinfection by-products (DBPs). In this study, capacitive disinfection is applied as a pre-treatment for O3 oxidation, in which manganese dioxide with a rambutan-like hollow spherical structure is used as the electrode to increase the charge density on the electrode surface. When a voltage is applied, the negative-charged microbes are attracted to the electrodes and killed by electrical interactions. The contact between microbes and capacitive electrodes leads to changes in cell permeability and burst of reactive oxygen species, thereby promoting the diffusion of O3 into the cells. After O3 penetrates the cell membrane, it can directly attack the cytoplasmic constituents, accelerating fatal and irreversible damage to pathogens. As a result, the performance of the capacitance-O3 process is proved better than the direct sum of the two individual process efficiencies. The design of capacitance-O3 system is beneficial to reduce the ozone dosage and DBPs with a broader inactivation spectrum, which is conducive to the application of ozone in primary water disinfection.
更多
查看译文
关键词
Ozone disinfection,Capacitive system,Manganese dioxide,Cell membrane,Bactericidal mechanism