Accuracy of routinely collected hospital administrative discharge data and death certificate ICD-10 diagnostic coding in progressive supranuclear palsy and corticobasal syndrome: a systematic review and validation study

Journal of Neurology(2024)

引用 0|浏览0
暂无评分
摘要
We conducted a systematic review to identify existing ICD-10 coding validation studies in progressive supranuclear palsy and corticobasal syndrome [PSP/CBS]) and, in a new study, evaluated the accuracy of ICD-10 diagnostic codes for PSP/CBS in Scottish hospital inpatient and death certificate data. Original studies that assessed the accuracy of specific ICD-10 diagnostic codes in PSP/CBS were sought. Separately, we estimated the positive predictive value (PPV) of specific codes for PSP/CBS in inpatient hospital data (SMR01, SMR04) compared to clinical diagnosis in four regions. Sensitivity was assessed in one region due to a concurrent prevalence study. For PSP, the consistency of the G23.1 code in inpatient and death certificate coding was evaluated across Scotland. No previous ICD-10 validation studies were identified. 14,767 records (SMR01) and 1497 records (SMR04) were assigned the candidate ICD-10 diagnostic codes between February 2011 and July 2019. The best PPV was achieved with G23.1 (1.00, 95
更多
查看译文
关键词
Progressive supranuclear palsy,Corticobasal degeneration,Positive predictive value,Sensitivity,ICD-10 diagnostic codes,Death certificate