Development of New Open-Set Speech Material for Use in Clinical Audiology with Speakers of British English.

Audiology research(2024)

引用 0|浏览0
暂无评分
摘要
BACKGROUND:The Chear open-set performance test (COPT), which uses a carrier phrase followed by a monosyllabic test word, is intended for clinical assessment of speech recognition, evaluation of hearing-device performance, and the fine-tuning of hearing devices for speakers of British English. This paper assesses practice effects, test-retest reliability, and the variability across lists of the COPT. METHOD:In experiment 1, 16 normal-hearing participants were tested using an initial version of the COPT, at three speech-to-noise ratios (SNRs). Experiment 2 used revised COPT lists, with items swapped between lists to reduce differences in difficulty across lists. In experiment 3, test-retest repeatability was assessed for stimuli presented in quiet, using 15 participants with sensorineural hearing loss. RESULTS:After administration of a single practice list, no practice effects were evident. The critical difference between scores for two lists was about 2 words (out of 15) or 5 phonemes (out of 50). The mean estimated SNR required for 74% words correct was -0.56 dB, with a standard deviation across lists of 0.16 dB. For the participants with hearing loss tested in quiet, the critical difference between scores for two lists was about 3 words (out of 15) or 6 phonemes (out of 50).