Expect the unexpected: investigating discordant prostate MRI and biopsy results

European Radiology(2024)

引用 0|浏览1
暂无评分
摘要
To evaluate discrepant radio-pathological outcomes in biopsy-naïve patients undergoing prostate MRI and to provide insights into the underlying causes. A retrospective analysis was conducted on 2780 biopsy-naïve patients undergoing prostate MRI at a tertiary referral centre between October 2015 and June 2022. Exclusion criteria were biopsy not performed, indeterminate MRI findings (PI-RADS 3), and clinically insignificant PCa (Gleason score 3 + 3). Patients with discrepant findings between MRI and biopsy results were categorised into two groups: MRI-negative/Biopsy-positive and MRI-positive/Biopsy-negative (biopsy-positive defined as Gleason score ≥ 3 + 4). An expert uroradiologist reviewed discrepant cases, retrospectively re-assigning PI-RADS scores, identifying any missed MRI targets, and evaluating the quality of MRI scans. Potential explanations for discrepancies included MRI overcalls (including known pitfalls), benign pathology findings, and biopsy targeting errors. Patients who did not undergo biopsy (n = 1258) or who had indeterminate MRI findings (n = 204), as well as those with clinically insignificant PCa (n = 216), were excluded, with a total of 1102 patients analysed. Of these, 32/1,102 (3
更多
查看译文
关键词
Prostatic neoplasms,Magnetic resonance imaging,Diagnostic errors,Critical pathways
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper