Assessing the sensitivity and specificity of myositis-specific and associated autoantibodies: a sub-study from the MyoCite cohort

Aravinthan Loganathan,Latika Gupta, Alex Rudge,Hui Lu, Elizabeth Bowler,Fionnuala McMorrow, R. Naveen, Anamika K. Anuja,Vikas Agarwal,Neil McHugh,Sarah Tansley

RHEUMATOLOGY(2024)

引用 0|浏览3
暂无评分
摘要
Objectives Myositis-specific and associated autoantibodies are important biomarkers in routine clinical use. We assessed local testing performance for myositis autoantibodies by comparing line immunoassay (LIA) to protein radio-immunoprecipitation and identifying clinical characteristics associated with each myositis autoantibody in the MyoCite cohort.Methods Serum samples from patients within the MyoCite cohort, a well-characterized retro-prospective dataset of adult and juvenile idiopathic inflammatory myopathy (IIM) patients in Lucknow, India (2017-2020), underwent LIA at Sanjay Gandhi Postgraduate Institute of Medical Science (SGPGIMS), Lucknow. Immunoprecipitation of 147 IIM patients' serum samples (125 adult-onset, 22 juvenile-onset) was conducted at the University of Bath, with researchers blind to LIA results. LIA performance was assessed against immunoprecipitation as the reference standard, measuring sensitivity, specificity and inter-rater agreement. Univariate and multivariate logistic regression determined clinical associations for specific myositis-specific autoantibodies.Results Immunoprecipitation identified myositis autoantibodies in 56.5% (n = 83) of patient samples, with anti-Jo1 (n = 16; 10.9%) as the most common, followed by anti-MDA5 (n = 14, 9.5%). While LIA showed good agreement for anti-Jo1, anti-PL7 and anti-PL12 (Cohen's kappa 0.79, 0.83 and 1, respectively), poor agreement was observed in other subgroups, notably anti-TIF1 gamma (Cohen's kappa 0.21). Strongly positive samples, especially in myositis-specific autoantibodies, correlated more with immunoprecipitation results. Overall, 59 (40.1%) samples exhibited non-congruence on LIA and immunoprecipitation, and kappa values for LIAs for anti-TIF1 gamma, anti-Ku, anti-PmScl, anti-Mi2 and anti-SAE ranged between 0.21 and 0.60.Conclusion While LIA reliably detected anti-Jo1, anti-PL7, anti-PL12, anti-MDA5 and anti-NXP-2, it also displayed false positives and negatives. Its effectiveness in detecting other autoantibodies, such as anti-TIF1 gamma, was poor.
更多
查看译文
关键词
inflammatory myositis,autoantibodies,immunoprecipitation clinical associations,Indian population,dermatomyositis,polymyositis,juvenile dermatomyositis
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要