The suitability of the hypoxico hyp123 altitude generator as a low oxygen delivery method for therapeutic acute intermittent hypoxia research trials

CHEST(2023)

引用 0|浏览4
暂无评分
摘要
SESSION TITLE: Respiratory Care Posters SESSION TYPE: Original Investigation Posters PRESENTED ON: 10/10/2023 12:00 pm - 12:45 pm PURPOSE: Therapeutic acute intermittent hypoxia (tAIH) is a novel treatment shown to elicit phrenic long-term facilitation in animal and human models. Improvement in non-respiratory motor neuron activity has also been demonstrated, and tAIH may improve motor function for people with spinal cord injury (SCI). Pre-clinical and preliminary clinical studies in SCI suggest that breathing short periods of low oxygen concentration (%O2) air stimulates hypoxia-induced neuroplasticity, strengthens motor neuron output, and improves clinical outcomes. Commercially available “altitude generators” have been used as a source of low %O2 air, however variable %O2 and flow rates have been noted. Study aims were to test the suitability of the altitude generator we planned to use in a clinical trial of tAIH, specifically the step-change response time (Experiment 1), %O2 variability (Experiment 2) and flow characteristics (Experiment 3). METHODS: Three bench-tests using a Hyp123 Altitude Generator with high altitude adapter (Hypoxico Altitude Training Systems), with air output sampled using a digital optical oxygen sensor (FDO2, PyroScience GmbH) connected to a data acquisition system (Spike2 version7, Micro 1401, Cambridge Electronic Design Ltd) were conducted. Experiment 1: The generator was set to deliver room air (21% O2), turned on and manually adjusted to deliver 9% O2. Five, six-minute trials were conducted and the T90 response time of the 21 to 9% O2 step change was calculated. Experiment 2: From a steady-state 9% O2 output, the % O2 variability (coefficient of variation (CV)) was measured over ten, two-minute trials. Experiment 3: Five, two-minute trials as per Experiment 2 were conducted with a pneumotachograph (Model 3700A, Hans Rudolph Inc) added to the circuit to record airflow. RESULTS: The altitude generator’s mean response time (T90) was 81.7 ± 3.8 seconds, with mean time to reach 9% O2 steady state of 179.8 ± 7.8 seconds. Minimal variability (CV = 0.01) was observed at steady-state 9% O2 target (9.0 ± 0.1% O2 [range 8.2 – 9.3%]). Airflow at 9% O2 was generated as a sinusoidal wave (2.5 second period) with trough and peak flow rates of 2.0 to 70.9 L/min (mean 34.9 ± 17.8 L/min). CONCLUSIONS: The Hypoxico Hyp123 Altitude Generator can generate low oxygen concentration air with minimal variability in %O2 once at a target steady-state of 9% O2. However, the device has a response time exceeding the commonly used tAIH protocol of 15, 60-second hypoxic episodes with 1-2 minute intervals of room air. Moreover, the generator does not output 9% O2 air at a steady flow rate, and trough values may be insufficient to meet an adult’s inspiratory flow rate during tidal breathing. CLINICAL IMPLICATIONS: Commercially available altitude generators may not be suitable for generating low oxygen concentration air required for tAIH research and translation to clinical environments. Alternative systems for delivering tAIH should be investigated. DISCLOSURES: No disclosure submitted for David Berlowitz No relevant relationships by Talia Clohessy No relevant relationships by Nicole Sheers
更多
查看译文
关键词
hypoxico hyp123 altitude generator,hypoxia,low oxygen delivery method
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要