[The consistency of skeletal muscle mass measured by CT at L 1 and L 3 levels and the correlation of skeletal muscle density at L 1 level with prognosis in dialysis patients].

M Yang, S M Hou, L Yuan,M Wang,J Zheng, K Q Lu, Y Yan,S Y Zhang,M Li, J Y Cao,M Yang, X L Zhang,H Liu,B C Liu,Y Wang,B Wang

Zhonghua yi xue za zhi(2023)

引用 0|浏览1
暂无评分
摘要
To investigate the consistency of skeletal muscle mass by CT at 1st lumbar vertebrae (L) and 3rd lumbar vertebrae (L) levels and the correlation of skeletal muscle density (SMD) at L level with prognosis in dialysis patients. A total of 1 020 patients who underwent initial dialysis and had CT examination data in four centers (Zhongda Hospital Affiliated to Southeast University, the Third Affiliated Hospital of Soochow University, Taizhou People's Hospital Affiliated to Nanjing Medical University and the Affiliated Hospital of Yangzhou University) from January 2014 to December 2019 were retrospectively collected. The skeletal muscle index (SMI) and SMD at L and L CT images were measured and calculated in patients with both L and L level CT images. The consistency of SMI and SMD at L and L levels was analyzed, and the cut-off value of SMI and SMD at L level for predicting all-cause mortality and their correlation with the prognosis of dialysis patients were studied. Cox regression model was used to analyze the risk factors for all-cause death and cardiac death. A total of 383 patients had both L and L level images, including 233 males and 150 females. The average SMD value of 16 samples (4.2%) exceeded the 95% consistency limit range (-8.71 to 7.75 HU), and the average SMI value of 15 samples (3.9%) exceeded the 95% consistency limit range (-20.45 to 9.53 HU). The optimal cut-off value of SMD at L level for predicting all-cause mortality was 36.46 HU and the area under curve (AUC) of receiver operating characteristic (ROC) curve was 0.658 (95%: 0.596-0.721, <0.001), with the sensitivity and specificity of 83.8% and 57.5%, respectively. SMI at L level was not significantly associated with all-cause mortality (=0.299). Multivariate Cox regression analysis showed that low SMD at L level was associated with all-cause mortality (=2.861, 95%: 1.576-5.193, =0.001) and cardiac death (=3.771, 95%:1.462-9.724, =0.006). SMD at L levelis consistent with SMD at L level and can be used to evaluate muscle mass. Low SMD is a risk factor for mortality in dialysis patients.
更多
查看译文
关键词
skeletal muscle density,skeletal muscle mass,dialysis patients
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要