Calibration method of relative linear deviation angle of polarizationthree-dimensional imager

Zhang Yue, Zhang Xue-Min, Liu Yi,Li Xuan, Zhang Su,Yu Yue,Jiao Jian-Chao,Su Yun

JOURNAL OF INFRARED AND MILLIMETER WAVES(2022)

引用 0|浏览0
暂无评分
摘要
Based on introduction about principle of polarization three-dimensional image and components of four aper-tures polarization three-dimensional imager, the influence of four apertures relative polarization direction on polarizationthree-dimensional imaging accuracy was analyzed, to determine the accuracy requirements for four apertures relative po-larization directions.The calibration method of relative polarization direction of four linear polarizers in four aperturelenses and calibration method of relative polarization direction of four apertures polarization three-dimensional imagerwas developed.The calibration device was built, and the relative polarization direction calibration was carried out in thelaboratory.The calibration error of relative polarization directions of four linear polarizers in four aperture lenses was +/- 0.5 degrees.The calibration error of relative polarization direction of four apertures polarization three-dimensional imager was +/- 1 degrees.Thus, the normal direction error of three-dimensional polarization inversion can be guaranteed to be -5.47%similar to 5.80%, that would ensure high-quality imaging of four apertures polarization three-dimensional imager
更多
查看译文
关键词
polarization three-dimensional image,relative polarization direction,four apertures,calibration method