Accurate Embolization for Endoleak after F-TEVAR of Thoracic Aortic Dissection by Detachable Coils.

Vascular(2023)

引用 0|浏览19
暂无评分
摘要
OBJECTIVES:To evaluate the efficacy and clinical outcomes of accurate embolization of endoleaks after fenestrated thoracic endovascular aortic repair (F-TEVAR) for thoracic aortic dissections. METHODS:Twenty patients with endoleaks (17 type I and 3 type II) after fenestrated thoracic endovascular aortic repair (F-TEVAR) were embolized using detachable and ordinary coils. We assessed the success rate and complications of the operation, and its effects, through clinical and CT follow-up. RESULTS:The mean clinical follow-up duration was 25.68 ± 11.07 months (3-44 months). During follow-up, all endoleaks were completely embolized and aortic remodeling was improved. Secondary endoleaks occurred in four patients who were embolized twice. No other complications or death were reported. CONCLUSION:Embolization using detachable and ordinary coils is effective and safe for the treatment of endoleaks after fenestrated thoracic endovascular aortic repair.
更多
查看译文
关键词
thoracic aortic dissection,aortic dissection,endoleak,f-tevar
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper