Development and characterization of a versatile mini-beam collimator for pre-clinical photon beam irradiation.

Medical physics(2023)

引用 0|浏览4
暂无评分
摘要
With the developed collimator, we achieved various mini-beam dose distributions that can be adjusted according to the needs of the user in regards to FWHM, ctc, PVDR and SCD, while accounting for beam divergence. Therefore, the designed mini-beam collimator may enable low-cost and versatile pre-clinical research on mini-beam irradiation.
更多
查看译文
关键词
3D printing, dosimetry, mini-beam collimator, spatial fractionation