Radiometric Calibration of GF5-02 Advanced Hyperspectral Imager Based on RadCalNet Baotou Site.

Remote. Sens.(2023)

引用 0|浏览5
暂无评分
摘要
In this study, an on-orbit radiometric calibration campaign of the GF5-02 AHSI was performed at the RadCalNet Baotou site, based on the automated observation of reflectance and atmospheric parameters of a 300 m × 300 m homogeneous desert area. The consistency of the radiometric calibration coefficients was validated both at the Dunhuang calibration site and the Baotou site. The average relative difference between the calibrated top-of-atmospheric (TOA) radiance and the predicted TOA radiance were less than 7%. The R2 of these two TOA radiances were all higher than 0.99. These results showed that the accuracy of calibration coefficients could meet the requirements of hyperspectral quantification applications. The uncertainty of GF5-02 AHSI radiometric calibration was 6.18%. This study also demonstrated that automated observation data of the Baotou site were reliable for high-frequency radiometric calibration and radiometric performance monitoring of GF5-02 AHSI.
更多
查看译文
关键词
GF5-02,AHSI,hyperspectral imager,radiometric calibration,RadCalNet
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要