Measurement System of the Mean and Sub-Cycle LV Grid Access Impedance From 20 kHz To 10 MHz

IEEE Transactions on Power Delivery(2023)

引用 3|浏览7
暂无评分
摘要
This work presents a novel measurement method to characterize long-term and short-term variations of the LV grid impedance from 20 kHz to 10 MHz with configurable time, frequency and amplitude resolutions. The characterization of the grid access impedance in this frequency range is vital for the design and development of NB-PLC and BB-PLC technologies. The measurement system is valid for in-home, indoor cable networks and for the harsh conditions of the LV distribution grid, where a large input dynamic range and strong protection mechanisms against high-amplitude impulsive noises are required. Its accuracy is evaluated by comparison to a precision impedance meter for a wide set of impedance values, obtaining a maximum deviation within ±8%. First trials of the grid impedance sub-cycle variations caused by commercial appliances and for frequencies assigned to BB-PLC are also presented in this paper. The results demonstrate that the grid impedance is highly time-varying within the mains cycle, both in amplitude and phase. These first outcomes point at the need to evaluate the accumulative effects of sub-cycle variations in the LV distribution grid, so that equalization algorithms in the next BB-PLC technologies could be developed to overcome the impact of these fast variations.
更多
查看译文
关键词
Communication channels,impedance measurement,low voltage,measurement techniques,power distribution networks,power line communications