No reflow phenomenon in CAD patients after percutaneous coronary intervention: A prospective hospital based observational study.

Shivani Rao, Rajeev Bhardwaj, P C Negi,Ranjit Kumar Nath

Indian heart journal(2023)

引用 0|浏览0
暂无评分
摘要
The present study assessed incidence, risk factors, in-hospital and short-term outcomes associated with no-reflow in patients undergoing percutaneous coronary intervention (PCI) in STEMI, NSTEMI, unstable angina and stable angina. Out of 449 patients, 42 (9.3%) developed no-reflow. Hypertension, dyslipidemia, obesity and smoking were significant risk factors. There was significant association of no-reflow with left main disease, multiple stents, target lesion length≥ 20 mm and higher thrombus grade. Interestingly, 93 patients (23.4%) of normal flow had myocardial perfusion grade (MPG) of 0/1 with mortality in 9 (10%) patients. No-reflow is associated with poor in-hospital and short-term outcomes with higher incidence of death, cardiogenic shock, heart failure and MACE. Knowledge of risk factors of no-reflow portends a more meticulous approach to improve final outcomes. MPG could be better predictor of outcomes in these patients.
更多
查看译文
关键词
No-reflow phenomenon,Percutaneous coronary intervention,Thrombolysis in myocardial infarction (TIMI)