Entry tear hemodynamics using 4D flow MRI in a patient with acute type B aortic dissection

Radiology Case Reports(2023)

引用 1|浏览6
暂无评分
摘要
Stanford type B aortic dissection (TBAD) is a potentially fatal condition involving a tear in the descending aorta. As TBAD can be managed with medical therapy or surgical repair, identifying predictors of adverse outcomes is important to risk-stratify patients for preemptive surgical procedures. 4D flow magnetic resonance imaging (MRI) has shown to be useful in characterizing the complex hemodynamics seen in TBAD patients and correlating flow patterns with adverse outcomes. We report a case of a 58-year-old man who presented to the hospital with acute TBAD and a large primary entry tear. He was initially managed with medical therapy due to his stable clinical status and computed tomographic angiography showing a stable dissection. However, 4D flow MRI showed high velocity flow through the entry tear, which foreshadowed the later clinical decompensation of the patient. Our case demonstrates that performing 4D flow MRI on TBAD patients is feasible and can provide valuable information in the decision to pursue medical or surgical management.
更多
查看译文
关键词
Type B aortic dissection,4D flow cardiac MRI,Cardiac MRI,Computed tomographic angiography,Magnetic resonance angiography