Diagnostic Accuracy of CT for Metastatic Epidural Spinal Cord Compression

CANCERS(2022)

引用 5|浏览20
暂无评分
摘要
Simple Summary Early diagnosis of metastatic epidural spinal cord compression (MESCC) is vital to prevent paralysis. Staging CT scans are performed routinely in cancer patients and could detect MESCC earlier. In this study, we assessed the performance of the original radiologist report for MESCC grading compared to three radiologists performing detailed MESCC evaluation using dedicated CT windows. Two expert radiologists provided the reference standard using MRI scans performed within 30 days. For normal/none versus low/high-grade MESCC per CT scan, all radiologists demonstrated almost perfect agreement with kappa values ranging from 0.866 (95% CI 0.787-0.945) to 0.947 (95% CI 0.899-0.995), compared to only slight agreement for the reports (kappa = 0.095, 95% CI-0.098-0.287). Radiologists also showed high sensitivities ranging from 91.51 (95% CI 84.49-96.04) to 98.11 (95% CI 93.35-99.77), compared to 44.34 (95% CI 34.69-54.31) for the reports. In conclusion, a dedicated radiologist review for MESCC on CT showed improved performance compared to the original report (current standard of care). Background: Early diagnosis of metastatic epidural spinal cord compression (MESCC) is vital to expedite therapy and prevent paralysis. Staging CT is performed routinely in cancer patients and presents an opportunity for earlier diagnosis. Methods: This retrospective study included 123 CT scans from 101 patients who underwent spine MRI within 30 days, excluding 549 CT scans from 216 patients due to CT performed post-MRI, non-contrast CT, or a gap greater than 30 days between modalities. Reference standard MESCC gradings on CT were provided in consensus via two spine radiologists (11 and 7 years of experience) analyzing the MRI scans. CT scans were labeled using the original reports and by three radiologists (3, 13, and 14 years of experience) using dedicated CT windowing. Results: For normal/none versus low/high-grade MESCC per CT scan, all radiologists demonstrated almost perfect agreement with kappa values ranging from 0.866 (95% CI 0.787-0.945) to 0.947 (95% CI 0.899-0.995), compared to slight agreement for the reports (kappa = 0.095, 95%CI -0.098-0.287). Radiologists also showed high sensitivities ranging from 91.51 (95% CI 84.49-96.04) to 98.11 (95% CI 93.35-99.77), compared to 44.34 (95% CI 34.69-54.31) for the reports. Conclusion: Dedicated radiologist review for MESCC on CT showed high interobserver agreement and sensitivity compared to the current standard of care.
更多
查看译文
关键词
metastatic spinal cord compression, epidural spinal cord compression, metastatic epidural spinal cord compression, spinal metastatic disease, spinal metastases classification, magnetic resonance imaging, MRI, computed tomography, CT, spine oncology study group, Bilsky classification
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要