Validating the ability of a portable shoe-floor friction testing device, NextSTEPS, to predict human slips.

Kurt E Beschorner,Arnab Chanda,Brian E Moyer, Alexander Reasinger,Sarah C Griffin, Isaiah M Johnston

Applied ergonomics(2022)

引用 6|浏览2
暂无评分
摘要
Measuring shoe-floor friction is critical for assessing the safety of footwear products. Portable devices for measuring coefficient of friction (COF) are needed. This study introduces such a device and evaluates its ability to predict human slip events across shoe designs. A portable device (18 kg) was utilized to measure 66 unique shoe-floor-fluid coefficients of friction (COF). Consistent with the shoes, flooring, and fluid contaminants from the COF tests, participants (n = 66) were unexpectedly exposed to the fluid while walking. Slip predictions were made based on a separate training data set. Slip predictions were made prospectively and using logistic regression analyses. The slip predictions were valid (p < 0.001), 91% sensitive, and 64% specific. The logistic regression fit also revealed that the COF values predicted slip outcomes (p = 0.006). This device is expected to expand the capacity of researchers, product developers, forensic engineers, and safety professionals to prevent slips and enhance human safety.