Novel isoelectric target depletion (ITaD) protocol reduces the need for specific reagents for immunogenicity testing

BIOANALYSIS(2022)

引用 1|浏览0
暂无评分
摘要
Background: The development of immunogenicity assays for clinical drug candidates targeting soluble proteins is challenging when the soluble target might produce either false-positive or false-negative signals in bridging anti-drug antibody screening assays. A generic soluble target removal protocol that uses a pH-dependent depletion was evaluated. Results: An anti-drug antibody bridging assay with a pH-dependent soluble target depletion step was successfully developed. Endogenous target levels of similar to 600 nM could be depleted below 8 pM. The assay was highly drug tolerant and met regulatory requirements. Conclusion: A reagent-independent target depletion protocol can be used for immunogenicity testing in the presence of a soluble target. The generic protocol circumvents common depletion or masking protocols.
更多
查看译文
关键词
anti-drug antibody, drug tolerance, ELISA, immunoassay, immunogenicity, LBA, soluble target