Analysis of pump-to-signal noise transfer in two-stage ultra-broadband optical parametric chirped-pulse amplification

OPTICS EXPRESS(2021)

引用 1|浏览7
暂无评分
摘要
In optical parametric chirped-pulse amplification (OPCPA), pump temporal intensity modulation is transferred to the chirped-signal spectrum via instantaneous parametric gain and results in contrast degradation of the recompressed signal. We investigate, for the first time to our knowledge, the pump-to-signal noise transfer in a two-stage ultra-broadband OPCPA pumped by a single laser and show the dependence of pump-induced signal noise, characterized both before and after pulse compression, on the difference in pump-seed delay in the two stages. We demonstrate an up-to-15-dB reduction of the pump-induced contrast degradation via pump-seed delay optimization. Experiments and simulations show that, even when parametric amplifiers are operated in saturation, the pump-seed delay can be used to minimize the pump-induced contrast degradation that is attributed largely to the noises from the unsaturated edges of the pulse and that of the beam. (C) 2021 Optical Society of America under the terms of the OSA Open Access Publishing Agreement