Measurements of the doses of eye lens for the workers of Fukushima Daiichi Nuclear Power Plant

RADIATION MEASUREMENTS(2020)

引用 2|浏览11
暂无评分
摘要
In Japan, the possibility to change the current dose limit of the lens of the eye for the radiation workers working in the planned exposure situation (normal controlled situations) to a new ICRP dose limit was discussed. It was further discussed how to appropriately monitor and manage the equivalent dose of the eye lenses for these workers exposed to radiation at their workplaces, such as nuclear and medical facilities. Among the workers exposed to a high-dose radiation at the water storage flange tank deconstructed Sr-90/Y-90 dominant areas and the nuclear reactor buildings (high dose gamma-ray) of the Fukushima Daiichi Nuclear Power Plant (1F-NPP), H-p(10), H-p(3), and H-p(0.07) at the head and the chest (or the upper arm) were estimated by passive personal dosimeters using thermoluminescence dosimeters (TLDs) and radio photoluminescence glass dosimeters (RPLGDs). The relationship between H-p(10), H-p(3), and H-p(0.07) along with the effects of the sites of wearing dosimeters on the head inside a full-face mask and the chest (or upper arm) were discussed.
更多
查看译文
关键词
Equivalent dose for the lens of the eye,Monitoring,Radiation workers,Fukushima Daiichi nuclear power plant (1F-NPP)
AI 理解论文