Design and construction of a new detector to measure ultra-low radioactive-isotope contamination of argon

C.E. Aalseth, S. Abdelhakim,F. Acerbi,P. Agnes,R. Ajaj,I.F.M. Albuquerque,T. Alexander,A. Alici,A.K. Alton, P. Amaudruz,F. Ameli,J. Anstey,P. Antonioli,M. Arba, S. Arcelli,R. Ardito,I.J. Arnquist,P. Arpaia,D.M. Asner, A. Asunskis,M. Ave, H.O. Back, V. Barbaryan,A. Barrado Olmedo, G. Batignani,M.G. Bisogni,V. Bocci,A. Bondar, G. Bonfini,W. Bonivento, E. Borisova,B. Bottino,M.G. Boulay,R. Bunker,S. Bussino,A. Buzulutskov,M. Cadeddu,M. Cadoni, A. Caminata,N. Canci,A. Candela, C. Cantini,M. Caravati, M. Cariello,F. Carnesecchi, M. Carpinelli, A. Castellani,P. Castello, S. Catalanotti,V. Cataudella, P. Cavalcante, D. Cavazza,S. Cavuoti,S. Cebrian,J.M. Cela Ruiz, B. Celano,R. Cereseto, W. Cheng, A. Chepurnov, C. Cicalò, L. Cifarelli, M. Citterio,F. Coccetti,A.G. Cocco, V. Cocco, M. Colocci,L. Consiglio, F. Cossio,G. Covone,P. Crivelli,I. D'Antone,M. D'Incecco,D. D'Urso,M.D. Da Rocha Rolo, O. Dadoun,M. Daniel, S. Davini,A. De Candia,S. De Cecco,M. De Deo,A. De Falco,G. De Filippis,D. De Gruttola,G. De Guido,G. De Rosa,G. Dellacasa,P. Demontis, S. DePaquale,A.V. Derbin, A. Devoto,F. Di Eusanio,L. Di Noto,G. Di Pietro,P. Di Stefano,C. Dionisi,G. Dolganov, F. Dordei,M. Downing, F. Edalatfar, A. Empl,M. Fernandez Diaz,A. Ferri,C. Filip,G. Fiorillo, K. Fomenko,A. Franceschi,D. Franco,G.E. Froudakis,F. Gabriele,A. Gabrieli, C. Galbiati,M. Garbini,P. Garcia Abia, D. Gascón Fora, A. Gendotti, C. Ghiano,A. Ghisi,S. Giagu,P. Giampa,R.A. Giampaolo,C. Giganti,M.A. Giorgi,G.K. Giovanetti,M.L. Gligan,A. Gola,O. Gorchakov,M. Grab,R. Graciani Diaz,F. Granato,M. Grassi,J.W. Grate, G.Y. Grigoriev,A. Grobov,M. Gromov, M. Guan,M.B.B. Guerra, M. Guerzoni, M. Gulino, R.K. Haaland,B.R. Hackett,A. Hallin, B. Harrop,E.W. Hoppe, S. Horikawa, B. Hosseini, F. Hubaut, P. Humble,E.V. Hungerford,An. Ianni,A. Ilyasov,V. Ippolito, C. Jillings, K. Keeter,C.L. Kendziora,S. Kim,I. Kochanek,K. Kondo,G. Kopp, D. Korablev,G. Korga,A. Kubankin, R. Kugathasan, M. Kuss,M. Kuźniak,M. La Commara,L. La Delfa,M. Lai,S. Langrock,M. Lebois, B. Lehnert, N. Levashko, X. Li, Q. Liqiang,M. Lissia, G.U. Lodi,G. Longo, R. López Manzano,R. Lussana,L. Luzzi, A.A. Machado,I.N. Machulin, A. Mandarano,L. Mapelli, M. Marcante, A. Margotti,S.M. Mari, M. Mariani,J. Maricic,M. Marinelli,D. Marras,M. Martínez,J.J. Martínez Morales,A.D. Martinez Rojas,C.J. Martoff,M. Mascia, J. Mason,A. Masoni, A. Mazzi, A.B. McDonald,A. Messina,P.D. Meyers,T. Miletic, R. Milincic,A. Moggi, S. Moioli,J. Monroe,M. Morrocchi,T. Mroz,W. Mu, V.N. Muratova,S. Murphy,C. Muscas, P. Musico, R. Nania,T. Napolitano,A. Navrer Agasson,M. Nessi,I. Nikulin,A. Oleinik,V. Oleynikov, M. Orsini,F. Ortica,L. Pagani,M. Pallavicini,S. Palmas,L. Pandola, E. Pantic,E. Paoloni, G. Paternoster, F. Pazzona,S. Peeters,P.A. Pegoraro,K. Pelczar, L.A. Pellegrini,C. Pellegrino,N. Pelliccia,F. Perotti,V. Pesudo,E. Picciau, C. Piemonte,F. Pietropaolo,A. Pocar,T.R. Pollmann,D. Portaluppi,S.S. Poudel, P. Pralavorio,D. Price,B. Radics,F. Raffaelli, F. Ragusa,M. Razeti,A. Razeto,V. Regazzoni, C. Regenfus,A.L. Renshaw,S. Rescia, M. Rescigno,F. Retiere, L.P. Rignanese,A. Rivetti,A. Romani,L. Romero,N. Rossi,A. Rubbia, D. Sablone,P. Sala,P. Salatino,O. Samoylov,E. Sánchez García,S. Sanfilippo, M. Sant,D. Santone,R. Santorelli,C. Savarese,E. Scapparone,B. Schlitzer, G. Scioli,E. Segreto,A. Seifert, D.A. Semenov,A. Shchagin,A. Sheshukov,S. Siddhanta,M. Simeone,P.N. Singh,P. Skensved,M.D. Skorokhvatov, O. Smirnov,G. Sobrero,A. Sokolov,A. Sotnikov, R. Stainforth, A. Steri, S. Stracka, V. Strickland, G.B. Suffritti,S. Sulis,Y. Suvorov, A.M. Szelc,R. Tartaglia, G. Testera, T. Thorpe, A. Tonazzo, A. Tosi,M. Tuveri, E.V. Unzhakov, G. Usai, A. Vacca,E. Vázquez-Jáuregui,M. Verducci, T. Viant,S. Viel,F. Villa,A. Vishneva,R.B. Vogelaar,M. Wada,J. Wahl, J.J. Walding,H. Wang,Y. Wang,S. Westerdale, R.J. Wheadon,R. Williams, J. Wilson,Marcin Wojcik,Mariusz Wojcik,S. Wu,X. Xiao, C. Yang,Z. Ye, M. Zuffa,G. Zuzel

JOURNAL OF INSTRUMENTATION(2020)

引用 15|浏览17
暂无评分
摘要
Large liquid argon detectors offer one of the best avenues for the detection of galactic weakly interacting massive particles (WIMPs) via their scattering on atomic nuclei. The liquid argon target allows exquisite discrimination between nuclear and electron recoil signals via pulse-shape discrimination of the scintillation signals. Atmospheric argon (AAr), however, has a naturally occurring radioactive isotope, Ar-39, a beta emitter of cosmogenic origin. For large detectors, the atmospheric Ar-39 activity poses pile-up concerns. The use of argon extracted from underground wells, deprived of Ar-39, is key to the physics potential of these experiments. The DarkSide-20k dark matter search experiment will operate a dual-phase time projection chamber with 50 tonnes of radio-pure underground argon (UAr), that was shown to be depleted of Ar-39 with respect to AAr by a factor larger than 1400. Assessing the Ar-39 content of the UAr during extraction is crucial for the success of DarkSide-20k, as well as for future experiments of the Global Argon Dark Matter Collaboration (GADMC). This will be carried out by the DArT in ArDM experiment, a small chamber made with extremely radio-pure materials that will be placed at the centre of the ArDM detector, in the Canfranc Underground Laboratory (LSC) in Spain. The ArDM LAr volume acts as an active veto for background radioactivity, mostly gamma-rays from the ArDM detector materials and the surrounding rock. This article describes the DArT in ArDM project, including the chamber design and construction, and reviews the background required to achieve the expected performance of the detector.
更多
查看译文
关键词
Noble liquid detectors (scintillation, ionization, double-phase),Dark Matter detectors (WIMPs, axions, etc.),Cryogenic detectors,Scintillators, scintillation and light emission processes (solid, gas and liquid scintillators)
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要