Calibration of phase contrast imaging on HL-2A Tokamak

Yan Yu,S.B. Gong, M. Xu, C.J. Xiao, W. Jiang,W.L. Zhong,Z.B. Shi,H.J. Wang,Y.F. Wu, B.D. Yuan, T. Lan,Minyou Ye,Xuru Duan

JOURNAL OF INSTRUMENTATION(2017)

引用 7|浏览15
暂无评分
摘要
Phase contrast imaging (PCI) has recently been developed on HL-2A tokamak. In this article we present the calibration of this diagnostic. This system is to diagnose chord integral density fluctuations by measuring the phase shift of a CO2 laser beam with a wavelength of 10.6 mu m when the laser beam passes through plasma. Sound waves are used to calibrate PCI diagnostic. The signal series in different PCI channels show a pronounced modulation of incident laser beam by the sound wave. Frequency-wavenumber spectrum is achieved. Calibrations by sound waves with different frequencies exhibit a maximal wavenumber response of 12 cm(-1). The conversion relationship between the chord integral plasma density fluctuation and the signal intensity is 2.3 x 10(13) m(-2)/mV, indicating a high sensitivity.
更多
查看译文
关键词
Plasma diagnostics - interferometry,spectroscopy and imaging,Nuclear instruments and methods for hot plasma diagnostics
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要