Assessing airflow rates of a naturally ventilated test facility using a fast and simple algorithm supported by local air velocity measurements

Building and Environment(2016)

引用 8|浏览32
暂无评分
摘要
The high spatial and temporal variations of airflow patterns in ventilation openings of naturally ventilated animal houses make it difficult to accurately measure the airflow rate. This paper focusses on the development of a fast assessment technique for the airflow rate of a naturally ventilated test facility through the combination of a linear algorithm and local air velocity measurements. This assessment technique was validated against detailed measurement results obtained by the measuring method of Van Overbeke et al. (2015) as a reference.
更多
查看译文
关键词
Natural ventilation,Ultrasonic anemometry,Animal houses,Airflow rates