Benchmark Experiments of Dose Distributions in Phantom Placed Behind Iron and Concrete Shields at the TIARA Facility

Journal of Nuclear Science and Technology(2014)

引用 0|浏览1
暂无评分
摘要
To verify the calculation methods used for the evaluations of neutron dose at the radiation shielding design of the high-intensity proton accelerator facility (J-PARC), dose distributions in a plastic phantom of 30 x 30 x 30 cm3 slab placed behind iron and concrete test shields were measured by using a tissue equivalent proportional counter for 65-MeV quasi-monoenergetic neutrons generated from the 7Li(p,n) reactions with 68-MeV protons at the TIARA facility. Dose distributions in the phantom were calculated by using the MCNPX and the NMTC/JAM-MCNP codes with the flux-to-dose conversion coefficients prepared for the shielding design of the facility. The comparison results show the calculated results were in good agreement with the measured ones within 20%.