Fault Current Measurements during Crush Testing of Electrically Parallel Lithium-Ion Battery Modules

ECS ELECTROCHEMISTRY LETTERS(2015)

引用 4|浏览24
暂无评分
摘要
Experimental data is presented from crush testing of 1S4P battery modules that quantifies the fault currents experienced by each cell after the onset of an internal short circuit. Combined with voltage and temperature measurements, the newly proposed method for measuring fault currents provides a more complete picture of the module failure during abusive crush. Short circuit resistance trends versus time are calculated from the current measurements, indicating approximately 20 milliohms resistance values prior to thermal runaway and resistive heat generation on the order of hundreds of watts. (C) The Author(s) 2015. Published by ECS. All rights reserved.
更多
查看译文
AI 理解论文