Evaluation of a novel wafer-scale CMOS APS X-ray detector for use in mammography

Nuclear Science Symposium and Medical Imaging Conference(2012)

引用 4|浏览11
暂无评分
摘要
The most important factors that affect the image quality are contrast, spatial resolution and noise. These factors and their relationship are quantitatively described by the Contrast-to-Noise Ratio (CNR), Signal-to-Noise Ratio (SNR), Modulation Transfer Function (MTF), Noise Power Spectrum (NPS) and Detective Quantum Efficiency (DQE) parameters. The combination of SNR, MTF and NPS determines the DQE, which represents the ability to visualize object details of a certain size and contrast at a given dose. In this study the performance of a novel large area Complementary Metal-Oxide-Semiconductor (CMOS) Active Pixel Sensor (APS) X-ray detector, called DynAMITe (Dynamic range Adjustable for Medical Imaging Technology), was investigated and compared to other three digital mammography systems (namely a) Large Area Sensor (LAS), b) Hamamatsu C9732DK, and c) Anrad SMAM), in terms of physical characteristics and evaluation of the image quality. DynAMITe detector consists of two geometrically superimposed grids: a) 2560 × 2624 pixels at 50 11m pitch, named Sub-Pixels (SP camera) and b) 1280 × 1312 pixels at 100 11m pitch, named Pixels (P camera). The X-ray performance evaluation of DynAMITe SP detector demonstrated high DQE results (0.58 to 0.64 at 0.5 Ip/mm). Image simulation based on the X-ray performance of the detectors was used to predict and compare the mammographic image quality using ideal software phantoms: a) one representing two three dimensional (3-D) breasts of various thickness and glandularity to estimate the CNR between simulated microcalcifications and the background, and b) the CDMAM 3.4 test tool for a contrast-detail analysis of small thickness and low contrast objects. The results show that DynAMITe SP detector results in high CNR and contrast-detail performance.
更多
查看译文
关键词
cmos digital integrated circuits,biomedical equipment,diagnostic radiography,mammography,noise,phantoms,sensors,3d breast,anrad smam,cdmam 3.4 test tool,dynamite cmos aps x-ray detector,dynamite subpixel detector,hamamatsu c9732dk,las,x-ray performance evaluation,active pixel sensor,complementary metal-oxide-semiconductor,digital mammography system,dynamic range adjustable for medical imaging technology,image contrast-to-noise ratio,image signal-to-noise ratio,image simulation,image spatial resolution,large area sensor,mammographic image quality,microcalcification,modulation transfer function,noise power spectrum,object visualization,software phantom,subpixel camera
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要