A lossless active clamping circuit for current doubler topologies

Power Electronics Letters, IEEE(2004)

引用 6|浏览11
暂无评分
摘要
This letter presents a new lossless clamping circuit on the secondary side for DC-DC converters with a current-doubler structure. This circuit reduces ringing on secondary-side rectifiers due to leakage inductance. The ringing loss is recovered to the load. As a result, efficiency is improved, and the voltage stress on secondary-side rectifiers is reduced significantly. These improvements allow DC-DC topologies with a current doubler to operate efficiently at high switching frequencies. The operating principle of the clamping circuit is detailed. Simulations and experimental results validate the proposed technique.
更多
查看译文
关键词
switching convertors,lossless active clamping circuit,current doubler topologies,dc,high switching frequency,dc-dc power convertors,rectifying circuits,65,current-doubler,secondary-side rectifier,clamping circuit,voltage stress,ringing loss,zero current switching,converter,dc&#,211,leakage inductance,dc-dc converter